What was found
LEFT WING, OTBD FLAP, OTBD FWD HINGE, WING SIDE, LOWER MOUNT OTBD BORE FOUND CORROSION. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE DIA: 0.618", FINAL HOLE DIA: 0.645" AND MAXIMUM ALLOWABLE HOLE DIA: 0.584". NEW REPAIR BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-T0326550, PT 1, STEP 1 & STEP 1A TITLE: WINGS, FLIGHT SURFACES, EO1-5750-7-5002. LEFT WING, OTBD FLAP, OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100. REFER TO WRI 57504780 FOR WORK DETAILS.