What was found
LEFT WING, INBD FLAP, OTBD AFT HINGE, FLAP SIDE, PIVOT INBD BORE FOUND CORROSION. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-52-03. EXISTING HOLE DIA: 1.188", FINAL HOLE DIA: 1.235" AND MAXIMUM ALLOWABLE HOLE DIA: 1.220". NEW REPAIR BUSHING FABRICATED AND INSTALLED IAW EA NR 1-5750-T0323098A, PT 4, STEP 1A & STEP 1D TITLE: WINGS, FLIGHT SURFACES, LT INBD FLAP OTBD HINGE BRACKET BORE INSPECTIONS. REPAIR CLASSIFIED AS MAJOR IAW GMM6-2-100, REFER TO WRI 57504793. FOR WORK DETAILS.