What was found
RT WING, OTBD FLAP, OTBD FORWARD HINGE LOWER MOUNT INBD BORE SURFACE AREA CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING THICKNESS: 0.414", MATERIAL REMOVED: 0.008", REMAINING THICKNESS: 0.406", MINIMUM ALLOWABLE, THICKNESS: 0.408", REPAIR SHIM FABRICATED AND INSTALLED IAW EA 1-5750-T0309816A, PART 2, STEP 1. TITLE: WINGS, FLIGHT SURFACES, EA 1-5750-7-5002, RT WING, OTBD FLAP, OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR GMM 6-2-100. REFER TO WRI: 57504779 FOR WORK DETAILS.