What was found
RT WING, OTBD FLAP, OTBD FWD HINGE LOWER MOUNT INBD CORRODED. REWORKED AND FOUND, EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE: DIA 0.521", FINAL HOLE: DIA 0.613", MAXIMUM ALLOWABLE HOLE: DIA 0.584". REPAIR BUSHING FABRICATED AND INSTALLED IAW EA NR 1-5750-T0309816, PART 2, STEP 1B AND STEP 1: TITLE: WINGS, FLIGHT SURFACES, EO 1-5750-7-5002, RT WING, OTBD FLAP-OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100. REFER TO WRI: 57504779 FOR WORK DETAILS.