What was found
RIGHT WING, OTBD FLAP, OTBD FWD HINGE UPPER MOUNT OTBD BORE CORRODED. REWORKED AND FOUND EXCEED LIMIT CMM 57-44-09. EXISTING HOLE: DIA 0.880". FINAL HOLE: DIA 0.953". MAXIMUM ALLOWABLE HOLE: DIA 0.944", REPAIR BUSHING FABRICATED AND INSTALLED IAW EA NR 1-5750-T0309816A, PART 2, STEP 1A. TITLE: WINGS-FLIGHT SURFACES, EO 1-5750-7-5002, RT WING, OTBD FLAP, OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100. REFER TO WRI: 57504779 FOR WORK DETAILS.