What was found
RT WING, OTBD FLAP, OTBD FWD HINGE UPPER MOUNT INBD BORE CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09. EXISTING HOLE: DIA 0.880", FINAL HOLE: DIA 0.953", MAXIMUM ALLOWABLE HOLE: DIA 0.944". REPAIR BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-T0309816A, PART 2, STEP 1A. TITLE: WINGS, FLIGHT SURFACES, EO 1-5750-7-5002, RT WING, OTBD FLAP, OTBD HINGE ASSY, WING SIDE, CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100. REFER TO WRI: 57504779 FOR WORK DETAILS.