What was found
RIGHT WING, INBD FLAP OTBD AFT HINGE, FLAP SIDE, PIVOT OTBD BORE FOUND CORROSION. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-52-03. EXISTING HOLE DIA: 1.289", FINAL HOLE DIA: 1.328" AND MAXIMUM ALLOWABLE HOLE DIA: 1.220". NEW REPAIR BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-69360B, PT 5, STEP 1A & STEP 1D, TITLE: WINGS - T/E & T/E DEVICES, RT INBD FLAP HINGE BRACKET ASSY, REPAIR. REPAIR CLASSIFIED AS MAJOR IAW GMM6-2-100. REFER TO WRI 57504794 FOR WORK DETAILS.