What was found
BS 1080 LT CREASE BEAM INNER SPICE FITTING FOUND CORRODED. CORROSION REMOVED IAW SRM 51-10-02-0G, REV 118.0 AND FOUND EXCEED LIMIT IAW SRM 53-40-12-1A, REV 118.0 FITTING. REMOVED IAW SRM 51-40-02-0G, REV 118.0 AND REPLACED IAW DWG 144N5200, SHT 1, REV B WITH FABRICATED FITTING. FITTING FABRICATED IAW DWG 144N5215, SHT 1, REV. REPAIR CLASSIFIED AS MAJOR.