What was found
MAIN DECK LEFT FRAME AT BS 1661 LONGERON 12L FOUND DAMAGED. FRAME REPAIRED IAW SRM 53-00-07-2R, FIG 201, REPAIR 2. REPETITIVE INSPECTION REQUIRED, INITIAL AT 14,500 CYCLES AND REPETITIVE, INSP AT EVERY 9,500 CYCLES TO BE CARRIED OUT IAW SRM 53-00-07-2R, TABLE 201, REPAIR 2 BY HFEC METHOD. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.