What was found
05 EA FASTENER HOLES, NR 6, 10, 12, 33, 34, FOUND CRACK INDICATION DURING HFEC OPEN-HOLE INSPECTION AT LT WING LOWER SKIN ACCESS DOOR CUTOUT BETWEEN STA XORS=683.4 AND STA XORS =713.6. REPAIR CARRIED OUT IAW SRM 57-20-02-2R, FIG 201, REPAIR 5. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100. INITIAL INSPECTION TO BE CARRIED OUT AT NEXT 2,000 CYCLES AFTER COMPLETION OF THIS REPAIR AND REPETITIVE INSPECTION AT EVERY 2,000 CYCLES IAW SRM 57-20-02-2R, TABLE 201/REPAIR 5.