What was found
BIRD STRIKE DENTED THE LT FORWARD FUSELAGE AT STA 148.5, WL 215. DENT MEASURES 6.4" X 3.5" X 0.336". REPAIRED DAMAGE IAW SRM 53-00-01, FIG 201, TABLE 5 WHICH REQUIRES REPETITIVE INSPECTION. CONTACT MOCC AFTER 30K FLT CYCLE INSPECTION TO SET UP 12K FLT CYCLE REINSPECT IAW SRM. REMOVE FROM IN-WORK, REF: SRM 53-00-01-2R, TERMINATING ACTION REQUIRED AT OR BEFORE: SPC: 28075 CYCLES EXP: 30,000 CYCLES, FACT 19AUG16 00:50. TERMINATING ACTION ACCOMPLISHED FOR SRM 53-00-01-2R AT 5,488:12 HRS, 1,936 CYCLES. PLEASE REFER TO EA H-5310-T0327433, REV A, PTS 3 AND PT 4 WILL TAKE OVER TRACKING FOR THE REPETITIVE INSPECTIONS. REPAIRED FUSELAGE USING SRM 53-00-01-2R, FIG 201, REPAIR 29 AS A REFERENCE.