What was found
DURING SERVICE CHECK, DISCOVERED EMERGENCY LIGHT TEST SWITCH ON P62 NLG PANEL INOPERATIVE. DURING TROUBLESHOOTING, FOUND LIGHT OXIDATION ON PIN SMALL C OF CONNECTOR D40488, CLEANED THE CONNECTOR. ALSO REPLACED TERMINAL ON WIRE W3054-0013-18 AT SWITCH S10035. SECURED THE CONNECTOR D40488 AND P62 PANEL. PERFORMED EMERGENCY LIGHTS OPS TEST, EMERGENCY LIGHTS OPS NORMAL, INCLUDING TEST SWITCH IAW SWPM CH20, WDM 33-51-11, AND AMM 33-51-00-5.