What was found
AT CRUISE, RECEIVED LEVEL 1 HYD OFF ALERT WITH 3.0 GALLONS REMAINING. AFTER NORMAL GEAR EXTENSION RECEIVED LEVEL 2 HYD FAIL ALERT AS ANTICIPATED. 1.4 GALLONS REMAINING IN NR 3 HYD RESERVOIR. CRASH, FIRE, RESCUE REPORTED HYDRAULIC LEAK FROM NR 3 ENGINE AREA INSTALLED NEW HOSE ASSY. MOTORED ENGINE, LEAK CHECK GOOD, REF MM 29-11-22. CLOSED THRUST REVERSER AND FAN COWL REF MM 71-10-00-2-1. RAN ENGINE IAW LEAK AND OPS CHECK GOOD, PN OF HOSE CHANGED WAS AEB794-167.