What was found
RIGHT CREASE BEAM WEB AT BS 967 - 975 RBL 69.5 FOUND CORROSION AROUND 3 RIVETS. REMOVED AND REPLACED IAW SRM 51-40-02-0G, REV 119.0 AND DWG 144N5140, SHEET 6. REV REPAIR CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT CREASE BEAM WEB AT BS 967 - 975 RBL 69.5 FOUND CORROSION AROUND 3 RIVETS. REMOVED AND REPLACED IAW SRM 51-40-02-0G, REV 119.0 AND DWG 144N5140, SHEET 6. REV REPAIR CLASSIFIED AS MAJOR.