What was found
DURING CLIMB, LOST ESSDC BUSS ,ECAM DIRECTED TO SELECT STBY GENERATOR,FAULT WHEN AWAY IN ABOUT 20 SECONDS. WE PRESSE ON. FAULT CAME BACK. LOST ESS DC AGAIN. DECLAIRED EMERGENCY. LOST MULTIPLE SYSTEMS. LANDED OK.#6 SPOILER FAULTED, NR 1 A/P WAS LOST NR 1 FD WAS LOST,LEFT AND RIGHT PROBE HEAT ON CAPT SIDE, PROBE HT CTR FAULTED AFTER LANDING. REMOVED AND REPLACED ESS TR IAW AMM 24-32-11-04. OP CHECKED NR 6 SPOILER IAW AMM. PERFORMED SPOILER TEST IAW AMM 27-64-14-04 PAR E. PERFORMED PROBE HEAT TEST IAW AMM 30-31-00-05. ALL OPS CHECKED GOOD. BOTH AP/FD OPS CHECK NORMAL IAW MM 22-40-00-05.