What was found
RIGHT WING OTBD FLAP, OTBD FWD HINGE, WING SIDE LOWER MOUNT, OTBD HOLE BORE CORROSION. HINGE REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING HOLE: DIA 0.582", FINAL HOLE: DIA 0.598", MAXIMUM ALLOWABLE HOLE: DIA 0.584". REPAIR BUSHING FABRICATED AND INSTALLED PER EA 1-5750-T0328318 PART 1 STEP 1A AND STEP 1. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.