What was found
RIGHT WING OTBD FLAP INBD FWD HINGE, WING SIDE LOWER MOUNT OTBD HOLE BORE CORROSION. HINGE REWORKED AND FOUND EXCEED LIMIT PER CMM 57-44-08. EXISTING HOLE: DIA 0.707", FINAL HOLE: DIA 0.729", MAXIMUM ALLOWABLE HOLE: DIA 0.709". REPAIR BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0328311 PART 1 STEP 1. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.