What was found
LEFT WING INBD FLAP, OTBD AFT HINGE, FLAP SIDE, PIVOT OTBD HOLE BORE CORRODED. REWORKED AND FOUND TO BE OUT OF LIMITS IAW CMM 57-52-03. A REPAIR BUSHING WAS FABRICATED AND INSTALLED IAW EA 1-5750-75300C P5, STEP 1A & STEP 1C. CLASSIFIED AS MAJOR IAW GMM 6-2-100.