What was found
AFT CARGO BS 1661-1681, STRINGER 28L CORRODED. REMOVED CORROSION IAW-SRM-51-10-02-0G, AFTER BLEND OUT, FOUND TO BE OUT OF LIMITS IAW SRM, NO ALLOWABLE LIMITS NOTED, REMOVED AND REPLACED THE STRINGER IAW SRM 51-40-02-0G AND DWG 146N3600. MAJOR REPAIR.