Service difficulty report · Indication Sys · Airbus A300F4605R

Difficulty date
January 4, 2017
Submitted
January 5, 2017
Operation
Air carrier
Aircraft
N686FE
Make and model
Airbus A300F4605R
Aircraft serial
804
Aircraft time
24,259 hours, 13,499 cycles
Part
Indication Sys
Part number
SIC50774
Condition
Malfunctioned
Location
Fuel Qty
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TRIM TANK ISOLATION VALVE NOT OPEN, ACCOMPANIED BY ALL X'S ON ECAM FUEL PAGE, TOTAL FUEL INDICATION, AND CG/GW INDICATIONS. ALSO,RT INNER AND RT OUTER INDICATIONS ON BACK-UP FUEL INDICATORS WERE BLANK. DIAGNOSED AS AN FQI FAULT. TRIPPED AND RESET CIRCUIT BREAKERS P60 AND P61 ON 132VU PANEL, THE FAULT CLEARED. PREFORMED AN OPERATIONAL (BITE) TEST IAW AMM 28-42-00-05-02, ONLY FAULT CODE 631, ACTUATOR 1 NOT INSTALLED. SYSTEM OPS NORMAL, ACFT OK TO CONTINUE.