What was found
RT WING OUTBD FLAP OUTBD FWD HINGE BRACKET SIDE ATTACH LOWER BORE FOUND CORROSION. CORROSION AT RT WING O/B FLAP O/B FWD HINGE BRACKET UPPER O/B MOUNT BORE. REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING HOLE DIA. 0.389", FINAL HOLE DIA. 0.409" MAXIMUM ALLOWABLE HOLE DIA 0.391". OVERSIZE BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0330790 PART 1 STEP 1C. TITLE: WINGS- FLIGHT SURFACES-EO 1-5750-7-5002-RT WING-OUTBD FLAP OUTBD HINGE (WINGSIDE) CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.