What was found
RT WING OUTBOARD FLAP OUTBOARD FORWARD HINGE BRACKET UPPER OUTBOARD MOUNT BORE FOUND CORROSION. HINGE BRACKET REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING HOLE DIA 0.943", FINAL HOLE DIA 0.952" MAXIMUM ALLOWABLE HOLE DIA 0.944 OVERSIZE BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0330790 PART 1 STEP 1A TITLE: WINGS-FLIGHT SURFACES EO 1-5750-7-5002 - RT WING - OUTBD FLAP OUTBD HINGE (WINGSIDE) - CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.