What was found
RT HAND WING OUTBD FLAP OUTBD FWD HINGE BRACKET UPPER INBOARD MOUNT BORE FOUND CORROSION. CORROSION AT RT WING O/B FLAP O/B FWD HINGE BRACKET UPPER INBD MOUNT BORE NR 2 HOLE. REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING HOLE DIA. 0.943", FINAL HOLE DIA. 0.952" MAXIMUM ALLOWABLE HOLE DIA 0.944 OVERSIZE BUSHING FABRICATED BY MACHINING AND INSTALLED AS PER EA 1-5750-T0330790 PART 1 STEP 1A TITLE: WINGS-FLIGHT SURFACES-EO 1-5750-7-5002 - RT WING - OUTBD FLAP OUTBD HINGE (WINGSIDE). CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.