What was found
AFTER FLOOR PANEL REMOVAL, FOUND STA 1790, X=75 SEAT TRACK CORRODED AT FLOOR PANEL CONTACT AREA. CORROSION REMOVED AS PER SRM 51-21-01-0G AND EXCEEDED LIMIT AS PER SRM 53-00-52-1A ALLOWABLE DAMAGE 1 FIGURE 101. REPAIR CARRIED OUT PER SRM 53-00-52-2R FIGURE 201, REPAIR 5. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.