What was found
DUE TO QRH PROCEDURES LEAVING CROSSFEED OPEN WITH LOW FUEL INDICATIONS, LANDED OUT OF TANK LIMITS. LEFT TANK, 7.8 RT TANK 4.6. IAW MOCC AND ENGN STICK FUEL QTY IN TANKS BOTH OUTER TANKS READING PER INDICATION L/H OUTER 7.5 AND STICK READING WAS 30 ON STICK OK.AND R/H OUTER IND READING 4.5 AND STICK READING 8 ON STICK. BOTH FROM STICK ML-1 IAW TROUBLESHOOTING, TRANSFERED FUEL OUT OF BOTH TANKS AND TRANSFERED BACK AND CHECKED FUEL IAW STICKS ALL MATCHED . PERFORMED ADJUSTMENT AND TEST FOR FUEL QTY INDICATION IAW AMM 28-42-00-05-02. PREFORMED LANDING IN EXCESS OF LATERAL IMBALANCE IAW 05-51-46-00 ALL SYSTEM CHECKED NORMAL. ACFT OK FOR SERVICE.