What was found
LT WING OUTBOARD FLAP OUTBOARD FORWARD HINGE (WING SIDE) LOWER MOUNT OUTBOARD BORE SURFACE CORROSION. HINGE REWORKED AND FOUND EXCEEDED LIMIT AS PER CMM 57-44-09. EXISTING THICKNESS 0.405", MATERIAL REMOVED 0.005", REMAINING THICKNESS 0.400". MINIMUM ALLOWABLE THICKNESS 0.408". SHOULDER BUSHING MACHINING AND INSTALLED AS PER EA 1-5750-T0331713 PART 1 STEP 2A AND STEP 2. REPAIR SHIM FABRICATED AND INSTALLED AS PER EA 1-5750-T0331713 PART 1 STEP 2. REPAIR CLASSIFIED MINOR PER GMM 6-2-100.