What was found
RT WING OUTBOARD FLAP OUTBOARD FORWARD HINGE (WING SIDE) LOWER MOUNT OUTBOARD BORE SURFACE CORROSION. HINGE REWORKED AND FOUND EXCEEDED LIMIT AS PER CMM 57-44-09. EXISTING THICKNESS 0.402" , MATERIAL REMOVED 0.008", REMAINING THICKNESS 0.394". MINIMUM ALLOWABLE THICKNESS 0.408". LOWER MOUNT INBD AND OUTBD BORE SHOULDER BUSHING (2 EA) FABRICATED AND INSTALLED AS PER EA 1-5750-T0331716 PART 1 STEP 2A AND STEP 2. LOWER MOUNT OUTBD BORE SURFACE SHIM FABRICATED AND INSTALLED AS PER EA 1-5750-T0331716 PART 1 STEP 2. REPAIR CLASSIFIED MINOR PER GMM 6-2-100.