What was found
CABIN, MAIN DECK CARGO COMPT FRAME EXISTING REPAIR CHAFED AT LT STA 535, LONGERON 24L. REPAIR ANGLE REPAIRED AS PER SRM 53-00-07-2R FIG 201 REPAIR 1. CHAFING MARKS ON OUTER REPAIR ANGLE EXCEEDED LIMITS AS PER SRM 53-00-00-2R FIG 202. ORIG THICKNESS: 0.125", MATERIAL REMOVED: 0.090", MATERIAL REMAINING: 0.035". REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100.