What was found
CORROSION FOUND ON FLOOR SUPPORT UPPER SURFACE OF TOP CAP FLANGES AROUND FASTENER HOLES BS 1040 - 1080, RBL 45. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, REV 120, AND DRAWING 144N8250.