What was found
ONE CRACK FOUND DURING HFEC INSPECTION ON THE TRANSVERSE SKIN AT STATION 5-0, LONGERON 1R CENTRE SPLICE AFT SIDE BETWEEN FASTENERS 6 AND 7. LONGERON 1R REMOVED IAW SRM 51-33-01- 0G . A SPLICE WAS FABRIACTED IAW DRAWING AEA 7634, REVISION B, AND INSTALLED IAW SRM 51-33-01-0G. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.