What was found
MAIN DECK, FRAME AT BS 535 LOWER REPAIR ANGLE CHAFED. THE REPAIR ANGLE WAS REMOVED IAW SRM 51-33-01-0G. A NEW REPAIR ANGLE WAS FABRICATED IAW SRM 53-20-07-2R, FIG 201, REPAIR 1, AND INSTALLED IAW SRM 53-20-07-2R, FIG 201, REPAIR 1. THE REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.