What was found
L1 AND R1 ESCAPE SLIDE RELEASE WARNING SYS LIGHTS INOPERATIVE. TROUBLESHOT IAW WDM 52-73-00, REMOVED CONTROL PANEL, AUTONOMOUS STBY POWER SUPPLY UNIT, CHECKED FOR 28 VDC AT PIN N. 28 VDC PRESENT. CLEANED THE CONTROL PANEL , CONNECTED & DOOR ECAM SLIDE NOW PRESENT WHEN DOOR IS ARMED & RED TEST LIGHTS ALSO ILLUMINATED ON BOTH DOORS. PERFORMED ADJUSTMENT AND TEST, R1 ECAM DISPLAY IAW AMM 52-71-00-05-09. ADJUSTED AND TESTED THE EMERGENCY ESCAPE SLIDE IAW AMM 52-73-00-05-01, ALL PASSED. OK TO CONTINUE.