What was found
MAIN DECK, FRAME26, Y37.52 TO Y17.72 HAS CORROSION ON THE PRESSURE DECK. REMOVED CORROSION ON THRUST BRACKET IAW SRM 51-74-10. FOUND TO BE OUT OF LIMITS IAW SRM 53-13-15. NO ALLOWABLE LIMITS. FABRICATED A NEW THRUST BRACKET IAW SRM 51-40-21, AND DWG A53781984. INSTALLED A NEW THRUST BRACKET IAW SRM 51-40-21. MAJOR REPAIR.