What was found
LOWER CENTER CARGO, UNDER THE FLOOR STRUCTURE AT STRINGER 50R, BS 1641 WAS FOUND CORRODED. REPAIRED IAW EA1-5310-T0334274 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER CENTER CARGO, UNDER THE FLOOR STRUCTURE AT STRINGER 50R, BS 1641 WAS FOUND CORRODED. REPAIRED IAW EA1-5310-T0334274 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.