What was found
EMERGENCY LIGHT TEST FAILED WITH EMERGENCY LIGHT BATTERY 1 LOW. REPLACED THE POWER SUPPLY IAW AMM 33-51-01-4, TESTED OK IAW AMM 33-50-00-5. ACFT OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHT TEST FAILED WITH EMERGENCY LIGHT BATTERY 1 LOW. REPLACED THE POWER SUPPLY IAW AMM 33-51-01-4, TESTED OK IAW AMM 33-50-00-5. ACFT OK FOR SERVICE.