What was found
LT WING O/B FLAP O/B FWD HINGE (WING SIDE) PIVOT BORE CORROSION. REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09 EXISTING HOLE: 2.3165", FINAL HOLE: 2.322", MAXIMUM ALLOWABLE HOLE: 2.3135". OVERSIZED BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0335621 PART 1 STEP 2B. FLIGHT SURFACES EO 1-5750-7-5002-LT WING OUTBD FLAP, OUTBD HINGE (WING SIDE) CORROSION REPAIR. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.