What was found
MAIN DECK CARGO DOOR MOST FWD HINGE SECTION ON FUSELAGE SIDE FOUND FWD 12EA HINGE LOBE HOLES WORN EXCEED LIMITS. STA 635- STA 652 WORN EXCEED LIMIT AT MAIN DECK CARGO DOOR MOST FWD HINGE SECTION ON FUSELAGE SIDE FWD 12EA HINGE LOBE HOLES REWORKED. FOUND NR 1 TO NR 6 HOLES EXCEED LIMITS AS PER CMM 52-34-04. OVERSIZE BUSHINGS FABRICATED BY MACHINING AND INSTALLED AS PER EA 1-5310-T0335809 PART 1. MAIN DECK CARGO DOOR JAMB WORN HOLES ON MAIN DECK CARGO DOOR FORWARD SUPPORT HINGE LOBE (FUSELAGE DOOR JAMB SIDE). REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100. REFER TO WRI 53107619 FOR WORK DETAILS.