What was found
DURING HFEC INSPECTION ON NOSE LANDING GEAR RT TRUNNION FTG SLOT OUT AREA, CRACK FOUND ON THE RADIUS PARALLEL TO THE SLOT OUT AREA APPROX 3/4 INCH LENGTH AS MARKED. CRACK AT NOSE LANDING GEAR RT TRUNNION FTG EXISTING SLOT OUT REPAIR AREA, REMOVED AND FOUND WITHIN LIMITS AS PER SRM 53-10-14-2R REPAIR 2 FIG 202 (LENGTH = 1.500" WITH=0.280") NEW REPAIR FILLER FABRICATED AND INSTALLED AT NOSE LANDING GEAR RT TRUNNION FTG STA 595 AS PER SRM 53-10-14-2R REPAIR 2 FIG 202. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.