As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT BETWEEN FR 11-13 AT Y334.5 HAS CORROSION IN HOLES AS MARKED. REMOVED CORROSION IAW SRM 51-74-10. CHECKED LIMITS L=2" W= 1" D= .050". FOUND OUT OF LIMITS IAW SRM 53-12-15. FABRICATED NEW FLOOR SUPPORT. LOCATED, DRILLED, AND DEBURRED IAW SRM 51-40-44. ALODINE AND PRIME IAW SRM 51-21-10. TOP COAT IAW SRM 51-75-10. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-21 MAJOR REPAIR.