What was found
MAIN DECK BETWEEN BS 1370 - 1415, LBL 64 CREASE BEAM CORRODED. D. REMOVED THE CORROSION. FOUND OUT OF LIMITS IAW SRM 53-60-13-1A, DET II AND III, CUT OUT DAMAGE SECTION FROM BS 1480 TO 1360 IAW SRM 53-00-13-2R. LOCATED AND DRILLED A NEW CREASE BEAM, CHANNEL, AND STRAP IAW SRM 53-00-13-2R, DETAIL I, FIG 201. INSTALLED THE NEW CREASE BEAM SECTION AND REPAIR PARTS IAW SRM 53-00-13-2R, DETAIL I, FIG 201.