What was found
MAIN DECK BS 1640 BETWEEN BL 0 - LBL 58.22 FLOORBEAM TEE CORRODED. REMOVED CORROSION IAW SRM 51-10-02-0G, LBL 38 TO LBL 58.22, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A, FIG 101, DETAL VI. CUT-OUT THE DAMAGED FLOORBEAM UPPER TEE, FABRICATED ANGLES, TEE REPAIR, TRIMMED, LOCATED, DRILLED, AND INSTALLED THE REPAIR IAW SRM 53-00-51-2R, FIG 201, REPAIR 8.