What was found
MAIN DECK STA 978 LT SIDE CUSP WEB CORRODED. REMOVED CORROSION AND EVALUATED CUSP WEB MAIN DECK AT STA 978 LT, ORIGINAL MAT .056", MAT REM .044" FOUND TO BE OUT OF LIMITS IAW SRM 53-40-13-1A DET II FIG 101. FORMED, LOCATED, DRILLED AND TRIMMED SHEAR WEB (CUSP WEB) IAW B DWG 144N5150 REV C REV A, INSTALLED NEW SHEAR WEB (CUSP WEB) IAW B DWG 144N5150 REV C AND REV A.