What was found
WITH STAB TRIM SET AT 2.5 DEGREES THE TAKE OFF CONFIGURAION TEST FAILED WHEN CHECKED ON TAXI OUT. WE CONFIRMED THE TRIM WAS CORRECT AND WAS SET ACCORDING TO APS. ECAM HAD INDICATED OUT OF TO RANGE AS REASON FOR FAILURE. WE RESET TRIM SETTING, VERIFIED THE IDEX WAS IN THE GREEN BAMD. A SECOND TO CONFIG TEST WAS SATISFACTORY. ON TO ROLL AT APPROX 100 KTS RECIEVED TO WARNING HORN W/NO ECAM INDICATION. ABORTED TAKE OFF AT APPROX 100 KTS AND 330,000 LBS. PERFORMED ADJUSTMENT OF MECHANICAL CONTROL OF THS REF A300-600 MM 27-40-00- 5AND 27-41-00-05 THRU STEPS 1. D (D) AND CHECKED CONTROL CABLES REF PARAGRAPH (2) A-E. ALL RIG PINS REMOVED AND TURNBUCKLES SAFTIED AT FRAME 20