What was found
NR 1 ENG FWD PYLON MOUNT HAS CORROSION IN BOLT HOLES. CLEANED NR 1 FWD ENGINE MOUNT HOLES IAW AMM 12-21-11-00, NO DAMAGE NOTED, REAMED AFT OUTBD HOLE TO DIA. 0.957" AND REMOVED CORROSION FOUND TO BE IN LIMITS IAW SRM 54-51-86 FIG 104, REPAIRED AFT INBD HOLE IAW SRM 54-51-81, FIG 202, THIS IS CLASSIFIED CAT "B" AND MAJOR REPAIR.