What was found
CRACK ON FLOOR STRUCTURE WEB IN FWD CARGO COMPT AT FR 37, -Y1470, UNDER FLOOR LEVEL. REMOVED WEB IN FWD CARGO COMPT AT FR-37 -Y1470 IAW SRM 51-40-21, FABRICATED WEB ON T18/1327252, INSTALLED WEB IAW SRM 51-40-21. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON FLOOR STRUCTURE WEB IN FWD CARGO COMPT AT FR 37, -Y1470, UNDER FLOOR LEVEL. REMOVED WEB IN FWD CARGO COMPT AT FR-37 -Y1470 IAW SRM 51-40-21, FABRICATED WEB ON T18/1327252, INSTALLED WEB IAW SRM 51-40-21. MAJOR REPAIR.