What was found
UNDER FLOOR PANEL 242YH AT -Y225, FRAME 47 WEB IS CRACKED. REMOVED AND REPLACED DAMAGED WEB IAW SRM 51-40-21. WEB FABRICATED ON T18/1334842 IAW SRM 53-15-15 CLASSIFIED AS A CAT "A" MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UNDER FLOOR PANEL 242YH AT -Y225, FRAME 47 WEB IS CRACKED. REMOVED AND REPLACED DAMAGED WEB IAW SRM 51-40-21. WEB FABRICATED ON T18/1334842 IAW SRM 53-15-15 CLASSIFIED AS A CAT "A" MAJOR REPAIR.