What was found
AFTER TAKE OFF, RECEIVED A LEVEL 1 HYD 1 OFF WARNING, FL 330. HYD 1 QTY 2.5. QTY DECREASED TO 0.0. RECIEVED LEVEL 2 HYD 1 FAIL. FOUND AFT LINE FROM OUTLET SIDE OF RT PUMP TO HYD MANIFOILD HAD CRACKED OUT AT THE REAR END AND CRACKED AT FRONT ON THE NR 1 ENGINE. REMOVED AND REPLACED ALL OF THE AFT LINES GOING TO UPPER PUMP. FOUND A BROKEN MOUNT ON THE OTBD LINE,