What was found
MAIN DECK AFT FLOOR SUPPORT AT STA 1914-2007, X = 22 FOUND CORROSION MARKED. CORROSION REMOVED AND FOUND EXCEED LIMIT PER SRM 53-00-00-2R FIG 206. FLOOR SUPPORT REMOVED PER SRM 51-31-01-0G. NEW FLOOR SUPPORT FABRICATED PER DRAWING AGA7088 REV B AND INSTALLED PER SRM 51-31-01-0G. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.