As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT O/B FLAP O/B FWD (WING SIDE) HINGE ACTUATOR O/B HOLE BORE FOUND WITH CORROSION. HINGE ACTUATOR O/B HOLE BORE (NR 8 HOLE) REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-09. EXISTING HOLE DIA 1.220", FINAL HOLE DIA 1.251", MAXIMUM ALLOWABLE HOLE DIA 1.220" . OVERSIZED BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0341019 PART 1 STEP 1D AND STEP 1. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.