What was found
LT O/B FLAP I/B FWD (WING SIDE) HINGE LOWER MOUNT I/B HOLE BORE FOUND WITH CORROSION. FWD HINGE LOWER MOUNT I/B HOLE BORE (NR 7 HOLE) REWORKED AND FOUND EXCEED LIMIT AS PER CMM 57-44-08. EXISTING HOLE DIA 0.650", FINAL HOLE DIA 0.713", MAXIMUM ALLOWABLE HOLE DIA 0.709". SHOULDER BUSHING FABRICATED AND INSTALLED AS PER EA 1-5750-T0341052 PART 1 STEP 2B, 2C AND STEP 2. REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.